Skip to main content

ECO-LINE EEi²

Maximised connectivity and intuitive touch display

Standardised energy sources with full range of functions and extensive I4.0 connectivity thanks to SIEMENS PLC. As easy to operate as a smartphone with EEi² interface.

State-of-the-art power electronics and control technology, Industry 4.0 connectivity, eQC modules for quality assurance and the stringent testing of all components make these generators top-class induction energy sources with maximum availability. With the eldec easy intuitive interface - EEi² for short - they are as easy to operate as a smartphone. They have a continuous output of 5 to 150 kW (MF) or 5 to 75 kW (HF), optionally time- and frequency-dependent power increase up to 50% (MF). ECO-LINE EEi² energy sources are available in a frequency range from 8 kHz to 400 kHz.

ECO-LINE EEi² generators are available with single or multiple outputs. Multiple outputs can be supplied as "2A" (two outputs, heating sequentially), as "x 2" (two outputs, heating simultaneously, independently of each other) or as ": 2" (two outputs, heating simultaneously, symmetrically).

The advantages of these powerful and robust energy sources are found in many details - from the high level of device protection through electrical isolation, and short-circuit-proof transistor technology to the precise energy metering and high efficiency.

Specifications ECO LINE EEi²

Intuitive handling with EEi² touchscreen

Power, frequency, current and voltage display

Control modes: power, temperature (PID)

Operation modes: Continuous, Tap, Timer

SIEMENS PLC, safety controller from Pilz

8 different timers, each min. 0.1 sec. to max. 9,999 sec. running time

Recipe management memory: up to 500 recipes

Housing in protection class IP20

Sensor signals for temperature detection 4-20 mA

External control and data exchange via Profinet interface

Flow and temperature monitoring of various water circuits

Short-circuit and open-circuit proof IGBT transistor technology

Automatic adaptation to resonance frequency

Circuit topology with electrical isolation

Precise energy output due to power setting in 1% steps

Energy transmission via flexible hose package 5 m (MF) and 3 m (HF)

Temperature and volume flow monitored fluid circuits with alarm function

Automatic adaptation and power regulation by pulse width modulation (MF) and pulse packet control (HF), even when exceeding the Curie temperature

Interfaces & connections: Pyrometer, foot switch, foot pedal, emergency stop 1-channel, re-cooling system, 24V, signal lamp 4 coloured.

Inverter efficiencies > 95% (depending on operating condition)

Options ECO-LINE EEI²

Control type: Current

Heat controller usable

Special coating possible

Foot pedal and/or foot switch

Pyrometer (single and multiple)

Mains voltage 200 V, 480 V. Others on request

Annealing cable (connection via cable box or directly)

Energy transmission via flexible hose package up to 15 m (MF) and 5 m (HF)

Adjustment range extension through serial / parallel switching (manual or automatic)

Profibus, EtherCat, other fieldbuses on request

Emergency stop 2-channel to external

Quick-change device coax / cable box

Adjustment range extension through switchable second frequency band

UL standard optionally available

eQC Moduls: eSM earth fault, ePM flux, ePM energy & eSM RFID

Remote maintenance

Temperature curves (100 pcs.)

Separate inductor cooling water supply

Quick coupling for cooling water connections

Protection for your generator

Our new Heavy Duty Field Case, HDFC for short. When the going gets rough.

More information

Technical Data ECO-LINE EEi² High Frequency

 Rated Capacity
(100%ED)     
Mains Connections
at 400V, 50Hz 
Required cooling
water without
inductor
Dimensions
B x H x T 
Weight
ECO-LINE-EEi² - XS HF 55 kW (HF)10 A8 l/min340 x 560 x 800 mm50 kg
ECO-LINE-EEi² - XS HF 1010 kW (HF)20 A8 l/min340 x 560 x 800 mm50 kg
ECO-LINE-EEi² - XS HF 1515 kW (HF)32 A8 l/min340 x 560 x 800 mm50 kg
      
ECO-LINE-EEi² - S HF 2525 kW (HF)50 A15 l/min590 x 560 x 800 mm80 kg
ECO-LINE-EEi² - S HF 3535 kW (HF)63 A15 l/min590 x 560 x 800 mm80 kg
      
ECO-LINE-EEi² - XL HF 5050 kW (HF)100 A27 l/min1170 x 560 x 800 mm120 kg
ECO-LINE-EEi² - XL HF 7575 kW (HF)160 A40 l/min1170 x 560 x 800 mm120 kg
      
"2A" – Two outputs, heat in sequence
      
ECO-LINE-EEi² - S HF 5 2A5 kW (HF)10 A50 l/min590 x 560 x 800 mm60 kg
ECO-LINE-EEi² - S HF 10 2A10 kW (HF)20 A50 l/min590 x 560 x 800 mm60 kg
ECO-LINE-EEi² - S HF 15 2A15 kW (HF)32 A50 l/min590 x 560 x 800 mm60 kg
      
ECO-LINE-EEi² - M HF 25 2A25 kW (HF)50 A50 l/min770 x 560 x 800 mm80 kg
ECO-LINE-EEi² - M HF 35 2A35 kW (HF)63 A50 l/min770 x 560 x 800 mm100 kg
      
"x2" – Two outputs, heat simultaneously and independently of each other
      
ECO-LINE-EEi² - M HF 5 x22 x 5 kW (HF)20 A50 l/min770 x 560 x 800 mm130 kg
ECO-LINE-EEi² - M HF 10 x22 x 10 kW (HF)32 A50 l/min770 x 560 x 800 mm130 kg
ECO-LINE-EEi² - M HF 15 x22 x 15 kW (HF)63 A50 l/min770 x 560 x 800 mm130 kg

 

 

Technical Data ECO-LINE EEi² Middle Frequency

 Rated Capacity
(100%ED)     
Mains Connections
at 400V, 50Hz 
Required cooling
water without
inductor
Dimensions
B x H x T 
Weight
ECO-LINE-EEi² - XS MF 55 kW (MF)10 A12 l/min340 x 560 x 800 mm50 kg
ECO-LINE-EEi² - XS MF 1010 kW (MF)20 A12 l/min340 x 560 x 800 mm50 kg
ECO-LINE-EEi² - XS MF 1515 kW (MF)32 A12 l/min340 x 560 x 800 mm50 kg
ECO-LINE-EEi² - XS MF 2020 kW (MF)40 A12 l/min340 x 560 x 800 mm50 kg
ECO-LINE-EEi² - XS MF 3030 kW (MF)63 A12 l/min340 x 560 x 800 mm50 kg
      
ECO-LINE-EEi² - S MF 2020 kW (MF)40 A12 l/min590 x 560 x 800 mm50 kg
ECO-LINE-EEi² - S MF 3030 kW (MF)63 A12 l/min590 x 560 x 800 mm50 kg
      
ECO-LINE-EEi² - M MF 5050 kW (MF)100 A29 l/min770 x 560 x 800 mm120 kg
ECO-LINE-EEi² - M MF 8080 kW (MF)160 A27 l/min770 x 560 x 800 mm120 kg
ECO-LINE-EEi² - M MF 7575 kW (MF)160 A29 l/min770 x 560 x 800 mm120 kg
      
ECO-LINE-EEi² - XL MF 100100 kW (MF)200 A37 l/min1170 x 560 x 800 mm170 kg
ECO-LINE-EEi² - XL MF 150150 kW (MF)315 A50 l/min1170 x 560 x 800 mm200 kg
      
"2A" – Two outputs, heat in sequence
      
ECO-LINE-EEi² - S MF 5 2A5 kW (MF)10 A50 l/min590 x 560 x 800 mm60 kg
ECO-LINE-EEi² - S MF 10 2A10 kW (MF)20 A50 l/min590 x 560 x 800 mm60 kg
ECO-LINE-EEi² - S MF 15 2A15 kW (MF)32 A50 l/min590 x 560 x 800 mm60 kg
ECO-LINE-EEi² - S MF 20 2A20 kW (MF)35 A50 l/min590 x 560 x 800 mm60 kg
ECO-LINE-EEi² - S MF 30 2A30 kW (MF)63 A50 l/min590 x 560 x 800 mm100 kg
      
ECO-LINE-EEi² - M MF 50 2A50 kW (MF)100 A30 l/min770 x 560 x 800 mm130 kg
ECO-LINE-EEi² - M MF 75 2A75 kW (MF)160 A30 l/min770 x 560 x 800 mm130 kg
      
ECO-LINE-EEi² - XL MF 100 2A100 kW (MF)200 A50 l/min1170 x 560 x 800 mm200 kg
ECO-LINE-EEi² - XL MF 150 2A150 kW (MF)315 A55 l/min1170 x 560 x 800 mm200 kg
      
"x2"– Two outputs, heat simultaneously and independently of each other
      
ECO-LINE-EEi² - M MF 5 x22 x 5 kW (MF)20 A50 l/min770 x 560 x 800 mm130 kg
ECO-LINE-EEi² - M MF 10 x22 x 10 kW (MF)32 A50 l/min770 x 560 x 800 mm130 kg
ECO-LINE-EEi² - M MF 15 x22 x 15 kW (MF)63 A50 l/min770 x 560 x 800 mm130 kg
ECO-LINE-EEi² - M MF 20 x22 x 20 kW (MF)80 A50 l/min770 x 560 x 800 mm130 kg
ECO-LINE-EEi² - M MF 30 x22 x 30 kW (MF)125 A50 l/min770 x 560 x 800 mm150 kg
      
ECO-LINE-EEi² - XL MF 50 x22 x 50 kW (MF)200 A50 l/min1170 x 560 x 800 mm150 kg
ECO-LINE-EEi² - XL MF 75 x22 x 75 kW (MF)315 A50 l/min1170 x 560 x 800 mm250 kg
      
":2"– Two outputs, simultaneous symmetrical heating
      
ECO-LINE-EEi² - S MF 15 :215 kW MF (7,5 kW je Koaxtrafo)32 A50 l/min590 x 560 x 800 mm60 kg
ECO-LINE-EEi² - S MF 20 :220 kW MF (10 kW je Koaxtrafo)35 A20 l/min590 x 560 x 800 mm60 kg
ECO-LINE-EEi² - S MF 30 :230 kW MF (15 kW je Koaxtrafo) 63 A20 l/min590 x 560 x 800 mm60 kg

 

 

Suitable tool: The new Heat Controller

Active feedback supports the reproducibility of hand-guided induction heating processes for the first time.

More information

Come and talk to us