Skip to main content

ECO-LINE EEI²

Maximised connectivity and intuitive touch display

Standardised energy sources with full range of functions and extensive I4.0 connectivity thanks to SIEMENS PLC. As easy to operate as a smartphone with EEI² interface.

State-of-the-art power electronics and control technology, Industry 4.0 connectivity, eQC modules for quality assurance and the stringent testing of all components make these generators top-class induction energy sources with maximum availability. With the eldec easy intuitive interface - EEI² for short - they are as easy to operate as a smartphone. They have a continuous output of 5 to 150 kW (MF) or 5 to 75 kW (HF), optionally time- and frequency-dependent power increase up to 50% (MF). ECO-LINE EEI² energy sources are available in a frequency range from 8 kHz to 400 kHz.

ECO-LINE EEI² generators are available with single or multiple outputs. Multiple outputs can be supplied as "-2A" (two outputs, heating sequentially), as "x 2" (two outputs, heating simultaneously, independently of each other) or as ": 2" (two outputs, heating simultaneously, symmetrically).

The advantages of these powerful and robust energy sources are found in many details - from the high level of device protection through electrical isolation, and short-circuit-proof transistor technology to the precise energy metering and high efficiency.

Specifications ECO LINE EEI²

Intuitive handling with EEI² touchscreen

Power, frequency, current and voltage display

Control modes: power, temperature (PID)

Operation modes: Continuous, Tap, Timer

SIEMENS PLC

8 different timers, each min. 0.1 sec. to max. 999 sec. running time

Recipe management memory: up to 500 recipes

Housing in protection class IP20

Sensor signals for temperature detection 4-20 mA

External control and data exchange via Profinet interface

Flow and temperature monitoring of various water circuits

Short-circuit and open-circuit proof IGBT transistor technology

Automatic adaptation to resonance frequency

Circuit topology with electrical isolation

Precise energy output due to power setting in 1% steps

Energy transmission via flexible hose package 5 m (MF) and 3 m (HF)

Temperature and volume flow monitored fluid circuits with alarm function

Automatic adaptation and power regulation by pulse width modulation (MF) and pulse packet control (HF), even when exceeding the Curie temperature

Interfaces & connections: Pyrometer, foot switch, foot pedal, re-cooling system, 24V, signal lamp 4 coloured.

Inverter efficiencies > 95% (depending on operating condition)

Options ECO-LINE EEI²

Control type: Current

Heat controller usable

Special coating possible

Foot pedal and/or foot switch

Pyrometer (single and multiple)

Mains voltage 200 V, 480 V. Others on request

Annealing cable (connection via cable box or directly)

Energy transmission via flexible hose package up to 15 m (MF) and 5 m (HF)

Adjustment range extension through serial / parallel switching (manual or automatic)

Profibus, EtherCat, other fieldbuses on request

Emergency stop 2-channel to external

Quick-change device coax / cable box

Adjustment range extension through switchable second frequency band

UL standard optionally available

eQC Moduls: eSM earth fault, ePM flux, ePM energy & eSM RFID

Remote maintenance

Temperature curves (100 pcs.)

Separate inductor cooling water supply

Quick coupling for cooling water connections

Housing in protection class IP54

graphical display of temperature curves, storage of up to 100 units

Protection for your generator

Our new Heavy Duty Field Case, HDFC for short. When the going gets rough.

More information

Technical data ECO-LINE EEI² High frequency

 Output power
(100%ED)
Mains connection
at 400V, 50Hz
Cooling water consumption
without inductor
Dimensions
H x W x D
weight
      
ECO-LINE EEI² XS HF 55 kW (HF)10 A6 l/min340 x 560 x 800 mm50 kg
ECO-LINE EEI² XS HF 1010 kW (HF)20 A10 l/min340 x 560 x 800 mm50 kg
ECO-LINE EEI² XS HF 1515 kW (HF)32 A12 l/min340 x 560 x 800 mm50 kg
      
ECO-LINE EEI² S HF 55 kW (HF)10 A6 l/min590 x 560 x 800 mm80 kg
ECO-LINE EEI² S HF 1010 kW (HF)20 A10 l/min590 x 560 x 800 mm80 kg
ECO-LINE EEI² S HF 1515 kW (HF)32 A12 l/min590 x 560 x 800 mm80 kg
ECO-LINE EEI² S HF 2020 kW (HF)50 A13 l/min590 x 560 x 800 mm80 kg
ECO-LINE EEI² S HF 3030 kW (HF)63 A14 l/min590 x 560 x 800 mm80 kg
      
ECO-LINE EEI² XL HF 5050 kW (HF)125 A21 l/min1170 x 560 x 800 mm120 kg
ECO-LINE EEI² XL HF 7575 kW (HF)160 A29 l/min1170 x 560 x 800 mm120 kg
ECO-LINE EEI² XL HF 9090 kW (HF)200 A34 l/min1170 x 560 x 800 mm120 kg
      
"-2A" - two outputs, heating one after the other
      
ECO-LINE EEI² S HF 5 -2A5 kW (HF)10 A6 l/min590 x 560 x 800 mm60 kg
ECO-LINE EEI² S HF 10 -2A10 kW (HF)20 A10 l/min590 x 560 x 800 mm60 kg
ECO-LINE EEI² S HF 15 -2A15 kW (HF)32 A12 l/min590 x 560 x 800 mm60 kg
      
"x2" - two outputs, heating simultaneously and independently of each other
      
ECO-LINE EEI² M HF 1.5 x22 x 1.5 kW (HF)10 A6 l/min770 x 560 x 800 mm130 kg
ECO-LINE EEI² M HF 5 x22 x 5 kW (HF)20 A12 l/min770 x 560 x 800 mm130 kg
ECO-LINE EEI² M HF 10 x22 x 10 kW (HF)50A20 l/min770 x 560 x 800 mm130 kg
ECO-LINE EEI² M HF 15 x22 x 15 kW (HF)63 A24 l/min770 x 560 x 800 mm130 kg
      
":2"- two outputs, simultaneous symmetrical heating
      
ECO-LINE EEI² S HF 5 :25 kW HF (2.5 kW per coaxial transformer)10 A6 l/min590 x 560 x 800 mm60 kg
ECO-LINE EEI² S HF 10 :210 kW HF (5 kW per coaxial transformer)20 A10 l/min590 x 560 x 800 mm60 kg
ECO-LINE EEI² S HF 15 :215 kW HF (7.5 kW per coaxial transformer)32 A12 l/min590 x 560 x 800 mm60 kg

Technical data ECO-LINE EEI² Medium frequency

 Output power
(100%ED)
Mains connection
at 400V, 50Hz
Cooling water consumption
without inductor
Dimensions
H x W x D
weight
      
ECO-LINE EEI² XS MF 55 kW (MF)10A6 l/min340 x 560 x 800 mm42 kg
ECO-LINE EEI² XS MF 1010 kW (MF)20 A10 l/min340 x 560 x 800 mm42 kg
ECO-LINE EEI² XS MF 1515 kW (MF)32 A12 l/min340 x 560 x 800 mm42 kg
ECO-LINE EEI² XS MF 2020 kW (MF)40 A13 l/min340 x 560 x 800 mm50 kg
ECO-LINE EEI² XS MF 3030 kW (MF)63 A14 l/min340 x 560 x 800 mm42 kg
ECO-LINE EEI² XS MF 20(30)30 kW (MF)40/63 A14 l/min340 x 560 x 800 mm42 kg
      
ECO-LINE EEI² S MF 55 kW (MF)10 A6 l/min590 x 560 x 800 mm50 kg
ECO-LINE EEI² S MF 1010 kW (MF)20 A10 l/min590 x 560 x 800 mm50 kg
ECO-LINE EEI² S MF 1515 kW (MF)32 A12 l/min590 x 560 x 800 mm50 kg
ECO-LINE EEI² S MF 2020 kW (MF)40 A13 l/min590 x 560 x 800 mm50 kg
ECO-LINE EEI² S MF 3030 kW (MF)63 A14 l/min590 x 560 x 800 mm50 kg
ECO-LINE EEI² S MF 20(30)30 kW (MF)40 / 63 A14 l/min590 x 560 x 800 mm50 kg
      
ECO-LINE EEI² M MF 4040 kW (MF)80 A19 l/min770 x 560 x 800 mm120 kg
ECO-LINE EEI² M MF 5050 kW (MF)100 A21 l/min770 x 560 x 800 mm120 kg
ECO-LINE EEI² M MF 50(80)80 kW (MF)100/160 A30 l/min770 x 560 x 800 mm120 kg
ECO-LINE EEI² M MF 7575 kW (MF)160 A29 l/min770 x 560 x 800 mm120 kg
      
ECO-LINE EEI² XL MF 100100 kW (MF)200 A37 l/min1170 x 560 x 800 mm170 kg
ECO-LINE EEI² XL MF 150150 kW (MF)300 A49 l/min1170 x 560 x 800 mm200 kg
      
"-2A" - two outputs, heating one after the other
      
ECO-LINE EEI² S MF 5 -2A5 kW (MF)10 A6 l/min590 x 560 x 800 mm60 kg
ECO-LINE EEI² S MF 10 -2A10 kW (MF)20 A10 l/min590 x 560 x 800 mm60 kg
ECO-LINE EEI² S MF 15 -2A15 kW (MF)32 A12 l/min590 x 560 x 800 mm60 kg
ECO-LINE EEI² S MF 20 -2A20 kW (MF)35 A13 l/min590 x 560 x 800 mm60 kg
ECO-LINE EEI² S MF 30 -2A30 kW (MF)63 A14 l/min590 x 560 x 800 mm100 kg
ECO-LINE EEI² S MF 20(30) -2A30 kW (MF)40 / 63 A14 l/min590 x 560 x 800 mm100 kg
      
ECO-LINE EEI² M MF 40 -2A40 kW (MF)80 A19 l/min770 x 560 x 800 mm130 kg
ECO-LINE EEI² M MF 50 -2A50 kW (MF)100 A21 l/min770 x 560 x 800 mm130 kg
ECO-LINE EEI² M MF 50(80) -2A80 kW (MF)100/160 A30 l/min770 x 560 x 800 mm130 kg
ECO-LINE EEI² M MF 75 -2A75 kW (MF)160 A29 l/min770 x 560 x 800 mm130 kg
      
ECO-LINE EEI² XL MF 100 -2A100 kW (MF)200 A56 l/min1170 x 560 x 800 mm200 kg
ECO-LINE EEI² XL MF 150 -2A150 kW (MF)300 A76 l/min1170 x 560 x 800 mm200 kg
      
"x2" - two outlets, simultaneous and independent heating
      
ECO-LINE EEI² M MF 5 x22 x 5 kW (MF)20 A12 l/min770 x 560 x 800 mm130 kg
ECO-LINE EEI² M MF 10 x22 x 10 kW (MF)40 A20 l/min770 x 560 x 800 mm130 kg
ECO-LINE EEI² M MF 15 x22 x 15 kW (MF)63 A24 l/min770 x 560 x 800 mm130 kg
ECO-LINE EEI² M MF 20 x22 x 20 kW (MF)80 A26 l/min770 x 560 x 800 mm130 kg
ECO-LINE EEI² M MF 30 x22 x 30 kW (MF)125 A28 l/min770 x 560 x 800 mm150 kg
ECO-LINE EEI² M MF 20(30) x22 x 30 kW (MF)80/125 A28 l/min770 x 560 x 800 mm150 kg
      
ECO-LINE EEI² XL MF 40 x22 x 40 kW (MF)160 A38 l/min1170 x 560 x 800 mm150 kg
ECO-LINE EEI² XL MF 50 x22 x 50 kW (MF)200 A42 l/min1170 x 560 x 800 mm150 kg
ECO-LINE EEI² XL MF 50(80) x22 x 50(80) kW (MF)200/355 A60 l/min1170 x 560 x 800 mm250 kg
ECO-LINE EEI² XL MF 75 x22 x 75 kW (MF)300 A58 l/min1170 x 560 x 800 mm250 kg
      
":2"- two outputs, simultaneous symmetrical heating
      
ECO-LINE EEI² S MF 5 :25 kW MF (2.5 kW per coaxial transformer)10 A6 l/min590 x 560 x 800 mm60 kg
ECO-LINE EEI² S MF 10 :210 kW MF (5 kW per coaxial transformer)20 A10 l/min590 x 560 x 800 mm60 kg
ECO-LINE EEI² S MF 15 :215 kW MF (7.5 kW per coaxial transformer)32 A12 l/min590 x 560 x 800 mm60 kg
ECO-LINE EEI² S MF 20 :220 kW MF (10 kW per coaxial transformer)35 A13 l/min590 x 560 x 800 mm60 kg
ECO-LINE EEI² S MF 30 :230 kW MF (15 kW per coaxial transformer)63 A14 l/min590 x 560 x 800 mm60 kg
ECO-LINE EEI² S MF 20(30) :230 kW MF (15 kW per coaxial transformer)40/63 A14 l/min590 x 560 x 800 mm60 kg
      
ECO-LINE EEI² M MF 40 :240 kW MF (20 kW per coaxial transformer)80 A19 l/min590 x 560 x 800 mm130 kg
ECO-LINE EEI² M MF 50 :250 kW MF (25 kW per coaxial transformer)100 A21 l/min590 x 560 x 800 mm130 kg
ECO-LINE EEI² M MF 50(80) :280 kW MF (40 kW per coaxial transformer)100/160 A30 l/min590 x 560 x 800 mm130 kg
ECO-LINE EEI² M MF 75 :275 kW MF (37.5 kW per coaxial transformer)160A29 l/min590 x 560 x 800 mm130 kg

Suitable tool: The new Heat Controller

Active feedback supports the reproducibility of hand-guided induction heating processes for the first time.

More information

Come and talk to us

Make an appointment directly for a meeting via phone or MS Teams

Contact us